Close
Online message
If you have any needs, please leave a message and we will contact you as soon as possible。

Specification: 06/09P/09S/18
Rated pressure: 310~340 bar
Rated flow: 60~180 L/min
EHV06
High efficiency
Less volume, lighter weight
Precise controllability
Low pressure drop, less fuel consumption
Quick response
EHV09
High efficiency
Less volume, lighter weight
Precise controllability
Low pressure drop, less fuel consumption
Comfort and coordination
Nominal size | EHV06 | EHV09P | EHV09S | EHV18 | |
General | |||||
Structure | Stackable, load sensing, post pressure compensated | Stackable, proportional, load sensing, post pressure compensated | |||
Type of connection | ISO BSP thread, metric thread | ISO1179-1 | JISB2351-1 | ||
Mass (kg) | Inlet element | 4.27/5.3 | 3.4 | 9.2 | |
Middle section-General | 3.5 | / | / | / | |
Middle section-With relief valve | 5.58 | / | / | / | |
Middle section-With hydraulic operated check valve | 4.86 | / | / | / | |
Middle section hydraulic operation | / | 2.7 | 3.4 | 7.5 | |
Middle section E-H operation | / | 3.3 | 2.9 | 7.8 | |
End element | 0.27 | 3.2 | 5.7 | ||
Hydraulic | |||||
Nominal size | 6 | 9P | 09S | 18 | |
Rated flow | P (L/min): 60 | Q (L/min): 90 (ΔP=15bar) | Q (L/min): 90 (ΔP=15bar) | Q (L/min): 180 (ΔP=15bar) | |
A/B (L/min): 50 | |||||
Rated operating pressure at port | P /LS (bar) | 310 | / | / | / |
A/B (bar) | 310 | / | / | / | |
Max. operating pressure at port | P /LS (bar) | / | 280 | 280 | 320 |
A/B (bar) | / | 340 | 320 | 340 | |
T (bar) | / | 30 | |||
TS (bar) | / | Less than 2 | |||
Pilot pressure | a/b (bar) | / | Less than 35 | ||
X (bar) | / | 30 | |||
Electricity | |||||
·Electrical on/off: | ·Connection: Deutsch DT04-2P | ||||
·Protection class: IP69k·Supply voltage: 12 or 24VDC | |||||
·Electrical proportional: | ·Dither frequency required: 120Hz | Electrical proportional: | |||
·Hysteresis: Less than 3% | ·Dither frequency required: 100-200Hz | ||||
·Connection: Deutsch DT04-2P | ·Connection: Deutsch DT04-2P/AMP Junior-Timer | ||||
·Protection class: IP69k | ·Protection class: IP69k | ||||
·Control current @12VDC: 0~1800mA, @24VDC: 0~1200mA | ·Control current @12VDC:0~1500mA; @24VDC:0~750mA | ||||
Using environment | |||||
Hydraulic fluid | Mineral oil (HL, HLP) according to DIN 51524.Other hydraulic fluids, such as HEES (Synthetic Ester) according to VDMA 24568. | ||||
Hydraulic fluid temperature range (℃) | -20 ~ +80 | -20 ~ +90 | |||
Viscosity range ν (mm2/s) | 10 ~ 380 | ||||
Maximum permissible degree of contamination of the pressure fluid cleanliness class to ISO 4406 (C) | Class 20/18/15, we therefore recommend a filter with a minimum retention rate of β10 ≥ 70 | Class 20/18/15, we therefore recommend a filter with a minimum retention rate of β10 ≥ 75 |